Using tools from the international plumbing code ipc it s not that hard.
How to know the number of roof r drains.
Size horizontal storm drainage piping.
A high slope moves water more quickly and if gutters have trouble dealing with a lot of water in a short period of time an extra downspout can alleviate that issue.
Total roof area 500 by 200 100 000 sq.
Gutters come in many sizes.
When sizing roof drains the limiting factor for the amount of water each drain will carry away is the size of leader therefore increasing.
Determine rate of rainfall for this example use 4.
What is the general area of a flat 1 4 1 0 slope single ply roof for each roof drain ratio for the number of roof drains roof area.
And 4 area handled by each drain.
The 6 in 12 pitch factor 1 1 multiplied by 1 000 yields an effective area of 1 100 square feet.
The published roof drain flow rate based on the head of water above the roof drain shall be used to size the storm drainage system in accordance with section 1106.
2 total area of roof.
If the result is a fraction less use the next higher number.
When determining the number roof drains required recognize that the smaller the roof drain outlet diameter the more drains you will need.
Is there a rule of thumb for number of roof drains needed on flat roofs.
The flow rate used for sizing the storm drainage piping shall be based on the maximum anticipated ponding at the roof drain.
50 000 4 400 11 36.
2 estimate the roof drain outlet.
Zurn makes it easy to size roof drains.
Conversely the larger the drain outlet diameter the fewer you will need.
A large roof is going to move a lot of water which means the downspout locations may need to be adjust to compensate.
A house in chicago has a roof whose actual drainage area is 1 000 square feet.
3 size of leader required.
Next the roof area is divided by the area for each leader to determine the number of drains required.
Select number of roof drains and calculate the roof area sloped to each drain.
6 24 2014 david howard aia said.
The result is the number of drains needed.
The four things you will need to know are.
The number of roof drains required for the building.
Multiplying that number by the local maximum rainfall intensity 6 8 inches per hour yields an adjusted square footage of 7 480 square feet.
Determine 100 year 1 hour rainfall rate used for location of building.
Each leader must be large enough to handle the volume of water to be drained the greater the leader capacity the fewer roof drains are needed.
Take the roof s total square footage and divide by the total square footage handled by one drain.
How to calculate the quantity of drains required.
After studying building plan and physical.
1 rate of precipitation.